                            | 1.线圈数据 |  |  
                            | 1-1.额定电压 | 3 
                              to 48 VDC |  
                            | 1-2.线圈电阻 | Refer 
                              to table 1 |  
                            | 1-3.动作电压 | Refer 
                              to table 1 |  
                            | 1-4.释放电压 | Refer 
                              to table 1 |  
                            | 1-5.额定电力消耗 | 360,450 
                              to 720 mW |  
                            | 240mW(Gap0.8mm) |  
                            |  | 
                                 
                               |  
                      
                        
                          | 2-1.触点型式 | 1 Form A , 1 Form C |  
                          | 2-2.触点材料 | AgCdo |  
                          | 2-3.额定下载 | 12A 120VAC / 24 VDC 
                            ,10A/250VAC/24VDC 5A 120VAC Inductive(COSØ=0.4)
 |  
                          | 5A 
                            24VDC Inductive(L/R=7ms) |  
                          | TV-5 |  
                          | 2-4.最大转换电压 | 110 VDC / 250 VAC |  
                          | 2-5.最大转换电流 | 15A(GAP0.35mm)30A(GAP0.8mm) |  
                          | 2-6.最大转换功率 | 2500 VA , 
                            240W |  
                          | 2-7.初始接触电阻 | ≤50 mΩ. 
                            at 6 VDC 1A |  
                          | 2-8.耐久性(平均寿命) | 电气寿命 | 100,000 operations at 
                            nominal load (30 open/min.) |  
                          | 机械寿命 | 10,000,000 
                            operations(300 open/min.) |  
 
                      
                        
                          | 3-1.绝缘电阻 | Min.100MΩ 
                            .at 500 VDC |  
                          | 3-2.介质耐压 | 1,000VAC 
                            , 1min between open contacts 1,800VAC , 1min between contacts and coil
 |  
                          | 3-3.动作时间 | Max. 
                            10ms |  
                          | 3-4.释放时间 | Max. 
                            5ms |  
                          | 3-5.使用湿度范围 | -40 
                            to +85 ℃ |  
                          | 3-6.抗冲击性 | 耐久性 | 1,000m/s2 |  
                          | 强度 | 100m/s2 |  
                          | 3-7.抗振性 | 耐久性 | 10 
                            - 55 Hz ,1.5mm Double Amplitude |  
                          | 强度 | 10 
                            - 55 Hz ,1.5mm Double Amplitude |  
                          | 3-8.高温性能 | 80±2℃96hs |  
                          | 3-9.低温性能 | -40±2℃96hs |  
                          | 3-10.湿度 | 85%RH |  
                          | 3-11.重量 | 12gr. |  
                          | 3-12.安全认证 | UL,CSA,VDE,TUV |  
 
                      
                      
                        
                          
                            |  | 
                                
                                  
                                    | CONTACT 
                                      ARRANGEMENT A-1FORM A
 C-1FORM C
 |  
                                    | COIL 
                                      VOLTAGE DC3V , DC5V , DC6V , DC9V , DC12V , 
                                      DC24V,DC48V
 |  
                                    | ENCLOSURE NIL-FLUX FREE
 S-WASHABLE
 |  
                                    | RELAY 
                                      SERIES NIL-450mW
 B:A and 720mW GAP:0.8mm
 H:360mW
 |  |  
                        
                          
                            
                              | 订购代码 | 线圈电压 VDC
 | 线圈电阻 Ω 
                                +/- 10%
 | 动作电压 VDC
 | 释放电压 VDC
 | 功耗 mW
 |  
                              | HRS4TH-(S)-DC3V | 3 | 25 | 2.1 | 0.30 | 360 |  
                              | HRS4TH-(S)-DC5V | 5 | 70 | 3.5 | 0.50 |  
                              | HRS4TH-(S)-DC6V | 6 | 100 | 4.2 | 0.60 |  
                              | HRS4TH-(S)-DC9V | 9 | 225 | 6.3 | 0.90 |  
                              | HRS4TH-(S)-DC12V | 12 | 400 | 8.4 | 1.20 |  
                              | HRS4TH-(S)-DC24V | 24 | 1600 | 16.8 | 2.40 |  
                              | HRS4TH-(S)-DC48V | 48 | 6400 | 33.6 | 4.80 |  
                              | HRS4T-(S)-DC3V | 3 | 20 | 2.1 | 0.30 | 450 |  
                              | HRS4T-(S)-DC5V | 5 | 56 | 3.5 | 0.50 |  
                              | HRS4T-(S)-DC6V | 6 | 80 | 4.2 | 0.60 |  
                              | HRS4T-(S)-DC9V | 9 | 180 | 6.3 | 0.90 |  
                              | HRS4T-(S)-DC12V | 12 | 320 | 8.4 | 1.20 |  
                              | HRS4T-(S)-DC24V | 24 | 1280 | 16.8 | 2.40 |  
                              | HRS4T-(S)-DC48V | 48 | 5120 | 33.6 | 4.80 |  
                              | HRS4TB-(S)-DC6V | 6 | 50 | 4.2 | 0.6 | 720 |  
                              | HRS4TB-(S)-DC12V | 12 | 200 | 8.4 | 1.2 |  
                              | HRS4TB-(S)-DC24V | 24 | 800 | 16.8 | 2.4 |  
                        
                        
                        
                          
                            
                              | Note: This data is based on the max. allowable temperature for E 型号 insulation coil(115°C)
 |  回页首   |