OS5030

30MHz, 2Ch, Dual trace
6" rectangular CRT with internal graticule
Sensitivity 1mV/div
ALT triggering function in VERT mode
CH2 polarity inversion switch
High sensitivity X?Y mode
Sweep magnification (X 10)
TV sync. Separator circuit for stable TV signal observation
400V maximum input voltag

OS5030

CRT

- Configuration and useful screen : 6 inch rectangular screen with internal
  graticule, 8X10div.(1div = 1cm) marking for measurement of rise time, 2mm
  subdivisions along the central axis. - Acceleration potential : +1.9kv approx.
  (ref. Cathode)
- Phosphor : P31
- Focusing : provided
- Trace rotation : provided
- Intensity control : provided
Z-AXIS INPUT
(INTENSITY
MODULATION)
- Input signal : positive going signal decreases +5Vp-p or more signal
  cases intensity noticeable modulation at normal intensity setting
- Bandwidth : DC to 2MHz(-3dB)
- Coupling : DC
- Input impedance : 25kΩ - 30kΩ typical
- Maximum input voltage : 30V(DC + peak AC)
    VERTICAL
     DEFLECTION
- DC coupled(-3dB) : DC to 30MHz normal / DC to 10MHz magnified
  (CH 1 only)
- AC coupled(-3dB):10Hz to 30MHz normal / 10Hz to 10MHz magnified
  (CH 1 only)
- Modes : CH1, CH2, ADD, DUAL(CHOP : Time/div. switch from 0.2s to 1ms,
  ALT : Time/div. switch from 0.5ms to 0.2μs)
- Deflection factor (normal): 5mV/div. to 20V/div. in 12 calibrated steps of 1-2-5
   sequence. Continuously variable between steps at least 1:2.5 X 5.
- Deflection factor (5MAG): 1mV/div. to 4V/div. in 12 calibrated steps
  (CH1 only).
- Accuracy : normal ±3%, magnified : ±5%(CH 1 only)
- Input impedance : approx. 1MΩ in parallel with 30pF
- Maximum input voltage : direct 400V (DC + peak AC)
- Input coupling : AC, GND, DC
- Rise time : 17.5ns or less (35ns or less in 5MAG)
- CH1 output : 25mV/div. into 50Ω / DC to 10MHz(-3dB)
- Polarity inversion : CH2 only
    HORIZONTAL
    DEFLECTION
- Sweep mode : NORM, X-Y, X 10, Variable
- Time base A : 0.2μs/div. to 0.2s/div. in 19 calibrated steps of 1-2-5 sequence
  uncalibrated continuous control between steps at least 1:2.5
- Sweep magnification : 10 times(maximum sweep rate : 20ns/div.) 50ns/div.
   or 20ns/div. ±10%
- Accuracy : ±3%(0℃ to 35℃), ±5%(0℃~10℃, 35℃~40℃)
   / additional error for magnifier : ±2%
    TRIGGER
    SYSTEM
- Modes : AUTO, NORM, TV-V, TV-H
- Source : VERT(DUAL/ALT), CH1, LINE, EXT
- Coupling : AC
- Slope : + or -
- Sensitivity and frequency in AUTO, NORM 20HZ - 2MHz :
   0.5div. or 2div.(VERT) in INT/ 0.2Vp-p in EXT
- Sensitivity and frequency in AUTO, NORM 2Hz - 20MHz :
   1.5div. or 3div.(VERT) in INT/ 0.6Vp-p in EXT
- Sensitivity and frequency in AUTO, NORM 20MHz - 30MHz :
   2.5div. or 4div.(VERT) in INT/ 1Vp-p in EXT
- TV-V, TV-H : at least 1div. or 1.0Vp-p
- External trigger input impedance : 1MΩ ± 10%
- Maximum input voltage : 400V (DC + AC peak)
X-Y OPERATION
- Sensitivity : same as vertical deflection for both X-axis(CH1) and Y-axis
  (CH2) except accuracy ± 5% in X-axis - X-axis bandwidt : DC to 500kHz
  (-3dB)
- X-Y phase difference : 3° or less as DC to 50kHz
CALIBRATOR
- Probe adjustment : approx. 1kHz frequency(20%), 0.5V(10%) square wave
  with 40-50% duty ratio
POWER SUPPLY
- Line voltage range : 115V(98-125V) with 125V 1A fuse or 230V(198-250V)
  with 250V 0.5A fuse - Line frequency : 50/60Hz
- Power consumption : approx. 45W
PHYSICAL
CHARACTERISTICS
- Weight : 7.8kg
- Dimension : 316mm(W) X 143mm(H) X 406mm(L)
OTHERS
- Accessories including : Operation manual, Spare fuse, Power cord
- Optional accessories (sold separately) : Probe

TOP

 

首页网站导航最新上架畅货指南木工频道工具套装元器件实验套件工具超市仪器仪表电子辅料

宏研电子 版权所有 Copyright  2000-2026   <联系宏研>

宏研优选:https://shop111273883.taobao.com/ 京东店:http://hongyan-e.jd.com 阿里巴巴:http://hy383e.1688.com(诚信通)

桂林公司:桂林市七星区甲天下广场国展写字楼418室    邮编:541002    电话:0773-3836682    传真:0773-3822291

上海办事处:上海市黄浦区汉口路515号汇金大厦706/707室    邮编:200001    电话:021-63515828

微信号:82866407 询价手机:13122078786 咨询QQ:3270212760 E-Mail:hy3836@126.com